Showing 8 Verified Solutions for Telecom Infrastructure
48V System 48V DC to 220V 230V AC 3KVA Pure Sinewave Inverter for Telecom
CERoHSFCC

48V DC to 220V/230V AC 3KVA Pure Sine Wave Telecom Inverter

  • Input Voltage48V DC
  • Output Voltage220V / 230V AC
  • Rated Capacity3KVA / 2400W
  • Form Factor19-Inch 2U Rack
$374 - $415 Min. Order: 1 set
Inquire
High Power 19 Inch Rack Mount Telecom Inverter 15KVA
CERoHSFCC

19" Rack Mount High Capacity 15KVA Pure Sine Wave Inverter

  • Input Voltage48V / 110V / 220V DC
  • Output Voltage110V / 220V AC
  • Rated Capacity15KVA / 12KW
  • Cooling ModeIntelligent Fan
$900 - $1,000 Min. Order: 1 set
Inquire
120V Output 2U 3U Rack Mount Telecom Inverter 48VDC to 120VAC 3KVA
CERoHSFCC

2U Rack Mount 48V DC to 120V AC 3KVA Telecom Power Inverter

  • Input Voltage48V DC
  • Output Voltage120V AC (North America)
  • Rated Capacity3KVA / 2400W
  • MountingStandard 19" 2U
$435 - $465 Min. Order: 5 pieces
Inquire
Modular 19 Inch Telecom Inverter 1.25KVA to 10KVA
CERoHSFCC

19" Telecom Inverter 1.25KVA–10KVA Pure Sine Wave Series

  • Input Voltage24V / 48V / 110V / 220V DC
  • Output Voltage220V AC ± 1%
  • Efficiency> 90%
  • Bypass SwitchingStatic Transfer Switch
$311 - $1,164 Min. Order: 5 pieces
Inquire
High Power 2U Rack Mount 4KW 5KVA Communication Inverter
CERoHSFCC

2U Rack Mount 4KW / 5KVA Telecom Pure Sine Wave Inverter

  • Input Voltage24V / 48V / 110V / 220V DC
  • Output Voltage220V AC 50Hz/60Hz
  • Continuous Power4000W / 5KVA
  • ProtectionOverload, Short Circuit, Thermal
$480 - $520 Min. Order: 1 set
Inquire
Substation Rack Mount High Volt 110Vdc to 220V 230Vac 1KVA Inverter
CERoHSFCC

Substation Grade 110V DC to 220V AC 1KVA / 800W Inverter

  • Input Voltage110V DC (Substation standard)
  • Output Voltage220V / 230V AC
  • THD< 3% (Linear load)
  • Enclosure19-Inch Steel Chasis
$280 - $315 Min. Order: 1 piece
Inquire
220VDC Input 19 Inch 220Vdc Input to 220Vac Output Pure Sine Wave Inverter 3KVA
CERoHSFCC

19" 220V DC to 220V AC 3000VA / 2400W Pure Sine Inverter

  • Input Voltage220V DC
  • Output Voltage220V AC Single Phase
  • WaveformPure Sine Wave
  • CommunicationRS232 / RS485 / Dry Contact
$363 Min. Order: 1 piece
Inquire
Standard 2U Power Inverter DC 220V to AC 220V 1600W 2000VA
CERoHSFCC

Industrial DC 220V to AC 220V 1600W / 2000VA Rack Inverter

  • Input Voltage220V DC
  • Output Voltage220V AC 50Hz
  • Rated Power1600W (Surge 3200W)
  • IsolationGalvanic Input/Output Isolation
$296 Min. Order: 1 piece
Inquire
Engineering Specifications

Telecom Inverter Selection & Comparison Guide

Compare our core telecom inverter configurations to select the right fit for your DC distribution panel and critical load requirements.

Model Series Nominal DC Input AC Output Voltage Continuous Power Overload Capability Standard Rack Unit
VN-TEL-48/3K 48VDC (40-60VDC) 220V / 230VAC ± 1% 3000VA / 2400W 120% for 60s, 150% for 10s 19" 2U Rack Mount
VN-TEL-48/120V 48VDC (40-60VDC) 110V / 120VAC ± 1% 3000VA / 2400W 125% for 60s 19" 2U Rack Mount
VN-TEL-110/1K 110VDC (90-140VDC) 220VAC ± 1.5% 1000VA / 800W 120% for 60s 19" 1U / 2U Rack Mount
VN-TEL-220/2K 220VDC (175-275VDC) 220VAC ± 1% 2000VA / 1600W 130% for 30s 19" 2U Rack Mount
VN-TEL-220/3K 220VDC (175-275VDC) 220VAC ± 1% 3000VA / 2400W 120% for 60s 19" 2U Rack Mount
VN-TEL-MOD-15K 48V / 110V / 220VDC 110V / 220VAC Custom 15KVA / 12KW 150% for 10s 19" 4U or Integrated Cabinet
Production Excellence

Certified In-House Manufacturing & Testing Facility

Varnix Technology Co., Ltd. operates 10+ dedicated lines across a verified 1,229 m² workshop. Every telecom unit undergoes rigorous inspection from raw components to 100% full-load burn-in.

Raw Material Inspection Warehouse

1. Raw Material

AQL verification for genuine MOSFETs, transformers, and capacitors.

Precision PCB Welding Line 1

2. Welding Station 1

High-precision soldering ensuring structural joint integrity.

Automated PCB Welding Line 2

3. Welding Station 2

SMT and through-hole soldering with automated checks.

Chassis and Inverter Assembly Line 1

4. Assembly Phase 1

Modular enclosure and chassis integration for 19-inch racks.

Power Circuit Assembly Line 2

5. Assembly Phase 2

Heatsink and thermal compound application for cooling.

Wiring and Integration Assembly Line 3

6. Assembly Phase 3

Wire harness crimping, LCD harness, and terminal block fitting.

Automated Function Test Bench

7. Function Test

Full functional parameter verification: frequency, THD, and regulation.

Intermediate Function Check Station

8. Function Check

Overvoltage, undervoltage, and polarity protection confirmation.

Burn-in Aging Test Chamber

9. Aging (Burn-in) Test

100% full-load burn-in under thermal stress for 4-8 hours.

Dedicated High-Temp Aging Area

10. Elevated Aging Area

Screening out potential early component failures prior to shipment.

Oscilloscope Harmonic Analysis

11. Oscilloscope Test

Waveform calibration to ensure true pure sine wave with <3% THD.

Precision Multimeter Measurement

12. Multimeter Calib.

Calibrating output accuracy, ripple voltage, and leakage current.

Industrial Curing Oven

13. Industrial Oven

Conformal coating curing to protect against moisture and corrosion.

CNC Drilling Machine

14. Drilling & Metalwork

CNC drilling for customized rack mounting tabs and brackets.

Final Quality Inspection Desk

15. Final Inspection

Complete cosmetic, safety, labeling, and grounding checks.

Reinforced Export Packaging Line

16. Export Packing

Shock-absorbent foam and heavy-duty cartons for maritime and air transit.

Finished Goods Warehouse

17. Finished Goods

Organized inventory staging for immediate dispatch worldwide.

Need Custom Voltages or Telecom Engineering Specs?

Varnix Technology Co., Ltd. provides OEM/ODM solutions tailored to exact telecom cabinet specifications, bypass configurations, and regional standards.

Get Catalog